Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - HCBU - Preslab
Permit Number - TC-COM-0823-02100
Inspection Description - COT - HCBU - Preslab
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/13/2024 | COT - HCBU - Preslab | Passed | Concrete forms are set, footings are properly dug and clean of debris, vapor barrier is installed, rebar reinforcement is in place and supported off of ground, plumbing pipes are properly wrapped with foam, and Ufer ground is connected to 20' of rebar reinforcement in the bottom of the footing. Okay to pour concrete footings and slab on grade. |