Inspection Status: Passed
Inspection History: COT - HCBU - Exterior Clips/Sheathing
| Date |
Description |
Inspector |
Results |
Comments |
| 01/27/2025 |
COT - HCBU - Exterior Clips/Sheathing |
|
Passed |
1/27/25: Full Pass--All items on previous inspections have been corrected and are now complete. |
| 08/19/2024 |
COT - HCBU - Exterior Clips/Sheathing |
|
Re-inspection required |
Loose shear throughout. Add anchor bolts 6"-12" from every break in the bottom plate throughout. Add cripple studs underneath girder trusses. Stopped inspection. 8/19/2024 |
| 08/20/2024 |
COT - HCBU - Exterior Clips/Sheathing |
|
Partial Pass |
Partial pass. Pending cs16 straps from header in hallway, reinforce top plate. Provide double studs continuous support for girder trusses. Okay to proceed with lath. 8/20/2024 |
| 08/22/2024 |
COT - HCBU - Exterior Clips/Sheathing |
|
Partial Pass |
8/22/24: metal framing to plan okay to proceed with intermediates |