Inspection Status: Re-inspection required
Inspection History: COT - HCEL - Electrical Above Ceiling
Permit Number - TC-COM-0724-01425
Inspection Description - COT - HCEL - Electrical Above Ceiling
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/30/2024 | COT - HCEL - Electrical Above Ceiling | Re-inspection required | 9/30/24: properly secure flex duct with saddle straps, registers must be supported on three sides, MC must be supported 12" from box, plumbing not per plans missing sink, plastic garments required at plumbing going through metal framing members, all knock outs at j-boxes must be sealed, DWV not under test. Properly secure all metal framing. ADA blocking required at bathrooms. | |
10/02/2024 | COT - HCEL - Electrical Above Ceiling | Partial Pass | All corrections were made. Partial pass hard lids areas. Okay to proceed progress areas. 10/2/2024 |