Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Passed
Inspection History: COT - HCEL - Electrical Intermediate
| Date |
Description |
Inspector |
Results |
Comments |
| 01/22/2025 |
COT - HCEL - Electrical Intermediate |
|
Passed |
|
| 09/30/2024 |
COT - HCEL - Electrical Intermediate |
|
Re-inspection required |
9/30/24: properly secure flex duct with saddle straps, registers must be supported on three sides, MC must be supported 12" from box, plumbing not per plans missing sink, plastic garments required at plumbing going through metal framing members, all knock outs at j-boxes must be sealed, DWV not under test. Properly secure all metal framing. ADA blocking required at bathrooms. |
| 10/02/2024 |
COT - HCEL - Electrical Intermediate |
|
Partial Pass |
All corrections were made. Partial pass hard lids areas. Okay to proceed progress areas. 10/2/2024 |