Inspection Status: Re-inspection required

Inspection History: COT - LCBU - Framing

Permit Number - TC-COM-0625-01188

Inspection Description - COT - LCBU - Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
09/17/2025 COT - LCBU - Framing Re-inspection required Power actuated fasteners call to be every 12" o.c. Provide kickers on south and west walls. Detail 4 for the traffic impact door jamb not per plan. Missing screws at north wall studs bottom track. 9/17/2025
09/18/2025 COT - LCBU - Framing Partial Pass All approved, except door jamb that does not match approved plans; builder directed to obtain revision for as built conditions. OK to cover North wall; proceed at own risk at West wall.
09/29/2025 COT - LCBU - Framing Not Ready no documents in software
10/02/2025 COT - LCBU - Framing Partial Pass Revision submitted pending review, ok to proceed to final, will clear once stamped. Partial pass
10/29/2025 COT - LCBU - Framing Passed Revision stamped