Inspection History: COT - LCBU - Framing
Permit Number - TC-COM-0625-01165
Inspection Description - COT - LCBU - Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/16/2025 | COT - LCBU - Framing | Re-inspection required | 9-16-25: missing diagonal bracing at 48" o.c. together with flat strap on one side & track block piece at each end. See A4.0 Detail's 1 & 5 for information. Note: due to vandalism/theft, provide an updated framing plan showing fix to damaged section of exterior wall located at the north side of building together with electrical & mechanical plan. Also, An air balance report will now be required prior to issuing a C of O. |
|
| 09/25/2025 | COT - LCBU - Framing | Partial Pass | 9-25-25: framing for soffit approved. Okay to continue with construction at progress areas. | |
| 10/03/2025 | COT - LCBU - Framing | Partial Pass | 10-3-25: partial pass on racking-pending anchors on racking system. | |
| 10/03/2025 | COT - LCBU - Framing | Re-inspection required | 10-3-25: arrived on site at 625am-waited until 640am and left. | |
| 10/06/2025 | COT - LCBU - Framing | Re-inspection required | 10-6-25: Missing hilti anchors at west wall & spacing for racking layout not per plan-have architect look provide clarification for "parts racking spacing" or install maintaining 3' clearance. | |
| 10/07/2025 | COT - LCBU - Framing | Passed | Shelving system throughout. |