Inspection Status: Partial Pass

Inspection History: COT - HCPL - Plumbing Progress 

Permit Number - TC-COM-0624-01147

Inspection Description - COT - HCPL - Plumbing Progress 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
11/24/2025 COT - HCPL - Plumbing Progress  Partial Pass Mini splits 1,2,3and 5. Condensation lines on test.
Plumbing in wall at room numbers 169,126,127,128,123,116. Roof drains on northwest side all on test in walls. Okay to proceed progress areas. 11/24/2025
12/16/2025 COT - HCPL - Plumbing Progress  Re-inspection required 12-16-25: plumbing in wall and above ceiling at gang restrooms, Area A, LSS room, cash count room, ap office. Add hangers and isolators throughout gang restrooms and fix leak at east wall. LSS room- add isolators where DWV is lying against framing and add vertical supports at midpoint on south exterior wall.
12/17/2025 COT - HCPL - Plumbing Progress  Partial Pass 12-17-25: no corrections made at LSS room-see previous notes and DWV at east wall of gang restrooms where leak was detected at fitting not under test. Okay to drywall west half of gang restrooms, however, a reinspected for the east wall at gang restroom and LSS room required.
12/31/2025 COT - HCPL - Plumbing Progress  Partial Pass