Parcel: 132130500


Addresses:

755 E BENSON HY


Inspection Status: Re-inspection required

Inspection History: COT - LCBU - Building Final 

Permit Number - TC-COM-0623-01560

Inspection Description - COT - LCBU - Building Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/10/2024 COT - LCBU - Building Final  Re-inspection required 1/10/24: cover plates missing throughout, GFCI required within 6' of water source, panel schedule missing, GFCI at bathroom has no power, receptacle in office has ground and neutral reversed, anti tip missing at range, all light fixtures must be installed, drywall not installed near restroom do to leak on second floor.
03/19/2024 COT - LCBU - Building Final  Not Ready
04/09/2024 COT - LCBU - Building Final  Passed