Inspection History: COT - LCME - Mechanical Final 

Date Description Inspector Results Comments
06/10/2026 COT - LCME - Mechanical Final  Not Ready
08/03/2026 COT - LCME - Mechanical Final  Not Ready Building 6. Unit 112. Remove door were sub panel is n place. Provide new sub panel due to paint inside.
Laundry room. Provide ko seals at all knock outs at j boxes. Provide GFCI protection at all receptacles in laundry room. Remove all screws from dryer ducts.
Provide supports at line sets in mechanical room. Secure mc cable. Re secure flue collar. Provide individual pressure relief valve at water heaters. S trap at sink.
114 Provide anti tip at range. Remove door at closet with sub panel.