Permit: TC-COM-0526-00655

Parcel: 14021012F


Addresses:

5401 S PARK AV

Inspection Status: Passed

Inspection History: COT - HCBU - Framing

Date Description Inspector Results Comments
07/17/2026 COT - HCBU - Framing Passed 7-17-26: framing inspection approved.
10/15/2026 COT - HCBU - Framing Re-inspection required 10/15/26: have architect of record provide a letter to the city documenting RC Channels- spacing and type of screws. Plywood screws for lighting wells approved.
10/23/2026 COT - HCBU - Framing Partial Pass 10/23/26: RC channels approved. Okay to drywall but schedule a drywall screw inspection prior to tape & texture.
11/04/2026 COT - HCBU - Framing Partial Pass 11/4/26: verified A34's, H3's, LTS12's and blocking for additional supports at light boxes. RFI to be submitted to the city for review-I uploaded the detail as an attachment on IG Inspect. Okay to drywall light boxes at own risk but schedule a drywall screw inspection prior to tape & texture.
11/06/2026 COT - HCBU - Framing Partial Pass 11/6/26: drywall screw inspection approved. Okay to tape & texture.