Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-COM-0526-00653

Parcel: 14118658A


Addresses:

10084 E OLD VAIL RD

Inspection Status: Partial Pass

Inspection History: COT - LCEL - Electrical Underground 

Date Description Inspector Results Comments
10/07/2026 COT - LCEL - Electrical Underground  Partial Pass X5 1 " for future light poles. X1 3" for future EV charger. Approximately 40' west of electrical room. X7 2" from electrical room to new SES location. Continuos 3" all the way from SES to future transformer. All schedule 40 out of slab at 36" to top of pipes. Okay to backfill all progress areas. Shading required. Ensure caution tape is in place after 1st lift of compaction to lines out of slab. 10/7/2026
10/15/2026 COT - LCEL - Electrical Underground  Partial Pass 10/15/26: 25-1" schedule 40 electrical branch circuits at elevated cardio platform areas. Okay to backfill approximately 130' of open trench using shading materials.