Inspection Status: Re-inspection required
Inspection History: COT - LCEL - Electrical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/13/2025 |
COT - LCEL - Electrical Final |
|
Re-inspection required |
10-13-25: per plans subpanel location was to be installed in bedroom and not in hallway. Relocate sub-panel, provide panel schedule & install 2 missing receptacles in living room. |
| 10/14/2025 |
COT - LCEL - Electrical Final |
|
Re-inspection required |
Provide a receptacle left of sink. Provide two circuits at kitchen. Receptacles near stove are not gfci protected. Receptacle underneath sink needs to be gfci protected. Lower t stat to 48". Set smoke detectors in place. 10/14/2025 |
| 10/23/2025 |
COT - LCEL - Electrical Final |
|
Passed |
|