Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - LCEL - Electrical Final
Permit Number - TC-COM-0525-01077
Inspection Description - COT - LCEL - Electrical Final
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2025 | COT - LCEL - Electrical Final | Re-inspection required | 10-13-25: per plans subpanel location was to be installed in bedroom and not in hallway. Relocate sub-panel, provide panel schedule & install 2 missing receptacles in living room. | |
| 10/14/2025 | COT - LCEL - Electrical Final | Re-inspection required | Provide a receptacle left of sink. Provide two circuits at kitchen. Receptacles near stove are not gfci protected. Receptacle underneath sink needs to be gfci protected. Lower t stat to 48". Set smoke detectors in place. 10/14/2025 | |
| 10/23/2025 | COT - LCEL - Electrical Final | Passed |