Inspection Status: Re-inspection required

Inspection History: COT - LCBU - Framing

Permit Number - TC-COM-0524-00990

Inspection Description - COT - LCBU - Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/31/2024 COT - LCBU - Framing Re-inspection required 1-Corner stud has been scabbed with approximately 4" overlap to block nailed to actual corner stud; this allows a bow present at time of inspection. 2-Sheathing is damaged approximately 6" from corner thus contributing to bow. 3-Multiple sole plates are split and missing nuts/washers. 4-Interior corner stud is bowing inward. 5-Multiple studs are not connected to sole plates adequately.
08/09/2024 COT - LCBU - Framing Passed