Inspection Status: Re-inspection required
Inspection History: COT - HCPL - Plumbing Final
Permit Number - TC-COM-0523-01363
Inspection Description - COT - HCPL - Plumbing Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/08/2024 | COT - HCPL - Plumbing Final | Re-inspection required | 2/8/24: pending air balance report and water sterilization report, ADA Signage missing at bathrooms, Knee guards required per plans at all ADA compliant lavatory's, Receptacle under break room lavatory needs to be GFCI, receptacle behind cabinet needs to be brought out and installed properly. | |
02/15/2024 | COT - HCPL - Plumbing Final | Passed | 2/8/24: pending air balance report and water sterilization report, ADA Signage missing at bathrooms, Knee guards required per plans at all ADA compliant lavatory's, Receptacle under break room lavatory needs to be GFCI, receptacle behind cabinet needs to be brought out and installed properly. 2/15/24: corrections made. |