Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - HCBU - Building Final
Permit Number - TC-COM-0523-01363
Inspection Description - COT - HCBU - Building Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/08/2024 | COT - HCBU - Building Final | Re-inspection required | 2/8/24: pending air balance report and water sterilization report, ADA Signage missing at bathrooms, Knee guards required per plans at all ADA compliant lavatory's, Receptacle under break room lavatory needs to be GFCI, receptacle behind cabinet needs to be brought out and installed properly. | |
02/15/2024 | COT - HCBU - Building Final | Passed | 2/8/24: pending air balance report and water sterilization report, ADA Signage missing at bathrooms, Knee guards required per plans at all ADA compliant lavatory's, Receptacle under break room lavatory needs to be GFCI, receptacle behind cabinet needs to be brought out and installed properly. 2/15/24: corrections made. |