Permit: TC-COM-0423-01050

Parcel: 133181630


Addresses:

7052 E 4TH ST

Inspection Status: Re-inspection required

Inspection History: COT - LCBU - Building Final 

Date Description Inspector Results Comments
06/14/2023 COT - LCBU - Building Final  Re-inspection required 6/14/23: Waiting on Fire Dept to approve all fire requirements of a R-3 occupancy, smoke det cannot be within 3 feet of register, smoke det missing outside north bedroom, Kitchen and bathrooms outlets are not GFCI protected and this 1959 house is a 2-wire system, install blank cover over missing breaker in panel, provide a complete set of city approved plans large enough to be legible.
09/28/2023 COT - LCBU - Building Final  Not Ready 6/14/23: Waiting on Fire Dept to approve all fire requirements of a R-3 occupancy, smoke det cannot be within 3 feet of register, smoke det missing outside north bedroom, Kitchen and bathrooms outlets are not GFCI protected and this 1959 house is a 2-wire system, install blank cover over missing breaker in panel, provide a complete set of city approved plans large enough to be legible.

9/28/23: no one on site, house is locked and empty. I texted Remy and stated that I would be on site at 9:15.
10/03/2023 COT - LCBU - Building Final  Re-inspection required 6/14/23: Waiting on Fire Dept to approve all fire requirements of a R-3 occupancy, smoke det cannot be within 3 feet of register, smoke det missing outside north bedroom, Kitchen and bathrooms outlets are not GFCI protected and this 1959 house is a 2-wire system, install blank cover over missing breaker in panel, provide a complete set of city approved plans large enough to be legible.

10/3/23: all smoke det required to be interconnected. Waiting on Fire Dept final.

6/14/23: Waiting on Fire Dept to approve all fire requirements of a R-3 occupancy, smoke det cannot be within 3 feet of register, smoke det missing outside north bedroom, Kitchen and bathrooms outlets are not GFCI protected and this 1959 house is a 2-wire system, install blank cover over missing breaker in panel, provide a complete set of city approved plans large enough to be legible.

9/28/23: no one on site, house is locked and empty. I texted Remy and stated that I would be on site at 9:15.
10/05/2023 COT - LCBU - Building Final  Passed 10/5/23: OK to issue Certificate of Occupancy R-3 Group Home