Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - HCEL - Electrical Underground 

Permit Number - TC-COM-0423-01033

Inspection Description - COT - HCEL - Electrical Underground 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/11/2024 COT - HCEL - Electrical Underground  Re-inspection required 7/1/24: M.E.P inspection failed, secure electrical wiring 8" from receptacles, DVW not under test, Domestic water not under test, seal all penetrations through vapor barrier and top plates throughout, nail plates missing throughout, exhaust fans not wired in, grounding at electrical panels must be installed correctly, low voltage boxes not roughed in, properly terminate electrical wiring in boxes (sheathing must extend 1/2" into box), damaged wiring must be replaced, knockouts at panel must be sealed, Condensate drain must be appropriately supported midway in walls, fire blocking required at soffit. (All units except commercial unit.
7/11/24: seal all penetrations through vapor barrier, seal all penetrations through top plate, secure electrical wiring 8"from box, nail plates missing throughout. Per previous Notes. STOPPED INSPECTION MORE ITEMS MAY BE ADDED
08/09/2024 COT - HCEL - Electrical Underground  Not Ready 8/8/24 called because the proper inspection was not available
08/15/2024 COT - HCEL - Electrical Underground  Not Ready
11/06/2024 COT - HCEL - Electrical Underground  Not Ready