Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - LCEL - Outdoor Lighting
Permit Number - TC-COM-0423-01032
Inspection Description - COT - LCEL - Outdoor Lighting
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/10/2024 | COT - LCEL - Outdoor Lighting | Re-inspection required | Adjust door closers and place safety barricades as discussed 12/10/24: 2 20Amp circuits required at kitchen for small appliances, 90 degree fitting required at exterior condensate drain, properly secure mini split at platform, water heater pressure relief shall not terminate more then 6" above finish grade and less then 2X the pipe diameter, water heater enclosure not installed, hose bibs must be insane wrapped for UV Protection, |
|
12/13/2024 | COT - LCEL - Outdoor Lighting | Passed |