Inspection Status: Re-inspection required

Inspection History: COT - LCEL - Outdoor Lighting

Permit Number - TC-COM-0423-01032

Inspection Description - COT - LCEL - Outdoor Lighting

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
12/10/2024 COT - LCEL - Outdoor Lighting Re-inspection required Adjust door closers and place safety barricades as discussed
12/10/24: 2 20Amp circuits required at kitchen for small appliances, 90 degree fitting required at exterior condensate drain, properly secure mini split at platform, water heater pressure relief shall not terminate more then 6" above finish grade and less then 2X the pipe diameter, water heater enclosure not installed, hose bibs must be insane wrapped for UV Protection,
12/13/2024 COT - LCEL - Outdoor Lighting Passed