Inspection Status: Passed

Inspection History: COT - HCBU - Building Final 

Permit Number - TC-COM-0323-00830

Inspection Description - COT - HCBU - Building Final 

Inspection Status - Passed

Date Description Inspector Results Comments
06/03/2025 COT - HCBU - Building Final  Passed
10/24/2024 COT - HCBU - Building Final  Re-inspection required 10/24/24: condensate drains at roof need to be properly supported and coated, electrical whip at A/C units need to be properly secured, A/C units are being over amped, receptacle on roofs have no power, riser at roof not complete, roof drains need proper guards at drains, disconnect stands require roof coating at fasteners to roof, roof hatch requires extension pole, ADA requirements at bathrooms not met (grab bars, coat hooks, water closet greater than allowed 16-18 o.c from wall line), GFCI required at dishwasher, pool hand rails not properly fastened. Panel schedule not made up, air gap required at water heater, pressure relief valve at water heater must terminate in mop sink, water heater plumbing not per plans,
10/28/2024 COT - HCBU - Building Final  Partial Pass 10/24/24: condensate drains at roof need to be properly supported and coated, electrical whip at A/C units need to be properly secured, A/C units are being over amped, receptacle on roofs have no power, riser at roof not complete, roof drains need proper guards at drains, disconnect stands require roof coating at fasteners to roof, roof hatch requires extension pole, ADA requirements at bathrooms not met (grab bars, coat hooks, water closet greater than allowed 16-18 o.c from wall line), GFCI required at dishwasher, pool hand rails not properly fastened. Panel schedule not made up, air gap required at water heater, pressure relief valve at water heater must terminate in mop sink, water heater plumbing not per plans,
10/28/24: corrections made at club house ok for level 4 TCO