Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - HCBU - Building Final
Permit Number - TC-COM-0323-00830
Inspection Description - COT - HCBU - Building Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/24/2024 | COT - HCBU - Building Final | Re-inspection required | 10/24/24: condensate drains at roof need to be properly supported and coated, electrical whip at A/C units need to be properly secured, A/C units are being over amped, receptacle on roofs have no power, riser at roof not complete, roof drains need proper guards at drains, disconnect stands require roof coating at fasteners to roof, roof hatch requires extension pole, ADA requirements at bathrooms not met (grab bars, coat hooks, water closet greater than allowed 16-18 o.c from wall line), GFCI required at dishwasher, pool hand rails not properly fastened. Panel schedule not made up, air gap required at water heater, pressure relief valve at water heater must terminate in mop sink, water heater plumbing not per plans, | |
10/28/2024 | COT - HCBU - Building Final | Partial Pass | 10/24/24: condensate drains at roof need to be properly supported and coated, electrical whip at A/C units need to be properly secured, A/C units are being over amped, receptacle on roofs have no power, riser at roof not complete, roof drains need proper guards at drains, disconnect stands require roof coating at fasteners to roof, roof hatch requires extension pole, ADA requirements at bathrooms not met (grab bars, coat hooks, water closet greater than allowed 16-18 o.c from wall line), GFCI required at dishwasher, pool hand rails not properly fastened. Panel schedule not made up, air gap required at water heater, pressure relief valve at water heater must terminate in mop sink, water heater plumbing not per plans, 10/28/24: corrections made at club house ok for level 4 TCO |