Inspection Status: Re-inspection required
Inspection History: COT - HCME - Mechanical Final
Permit Number - TC-COM-0323-00830
Inspection Description - COT - HCME - Mechanical Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/24/2024 | COT - HCME - Mechanical Final | Re-inspection required | 10/24/24: condensate drains at roof need to be properly supported and coated, electrical whip at A/C units need to be properly secured, A/C units are being over amped, receptacle on roofs have no power, riser at roof not complete, roof drains need proper guards at drains, disconnect stands require roof coating at fasteners to roof, roof hatch requires extension pole, ADA requirements at bathrooms not met (grab bars, coat hooks, water closet greater than allowed 16-18 o.c from wall line), GFCI required at dishwasher, pool hand rails not properly fastened. Panel schedule not made up, air gap required at water heater, pressure relief valve at water heater must terminate in mop sink, water heater plumbing not per plans, | |
10/28/2024 | COT - HCME - Mechanical Final | Passed | 10/24/24: condensate drains at roof need to be properly supported and coated, electrical whip at A/C units need to be properly secured, A/C units are being over amped, receptacle on roofs have no power, riser at roof not complete, roof drains need proper guards at drains, disconnect stands require roof coating at fasteners to roof, roof hatch requires extension pole, ADA requirements at bathrooms not met (grab bars, coat hooks, water closet greater than allowed 16-18 o.c from wall line), GFCI required at dishwasher, pool hand rails not properly fastened. Panel schedule not made up, air gap required at water heater, pressure relief valve at water heater must terminate in mop sink, water heater plumbing not per plans, 10/28/24: corrections made at club house ok for level 4 TCO |