Inspection Status: Passed

Inspection History: COT - HCBU - Masonry Pregrout 

Date Description Inspector Results Comments
04/26/2024 COT - HCBU - Masonry Pregrout  Passed
11/16/2023 COT - HCBU - Masonry Pregrout  Partial Pass Elevator shaft. Elevator walls 2nd lift at 16'. Okay to grout per special inspection report. 11/16/2023
11/17/2023 COT - HCBU - Masonry Pregrout  Partial Pass Elevator shaft. Elevator walls 2nd lift at 16'. Okay to grout per special inspection report. 11/16/2023
11/17/23: Elevator shaft, elevator walls 3rd lift at 24'. Okay to grout per special inspection report.
11/28/2023 COT - HCBU - Masonry Pregrout  Partial Pass Elevator shaft. Elevator walls 2nd lift at 16'. Okay to grout per special inspection report. 11/16/2023
11/17/23: Elevator shaft, elevator walls 3rd lift at 24'. Okay to grout per special inspection report.
11/28/23: Elevator shaft, elevator walls 4th lift at 32'. Okay to grout per special inspection report.