Date Description Inspector Results Comments
09/28/2023 COT - HCBU - Masonry Pregrout  Partial Pass North, east and west stem wall. Rebar per plan. Okay for concrete placement. 9/28/2023
11/13/2023 COT - HCBU - Masonry Pregrout  Partial Pass 11-13-23: East, west, and south CMU Block walls are 8' high with horizontal and vertical rebar reinforcement in place for bond beams above doors, and ready for 2nd grout lift. Okay to proceed with grout pour.
11/16/2023 COT - HCBU - Masonry Pregrout  Partial Pass Third lift.
11/20/2023 COT - HCBU - Masonry Pregrout  Partial Pass North, east and west stem wall. Rebar per plan. Okay for concrete placement. 9/28/2023

11-13-23: East, west, and south CMU Block walls are 8' high with horizontal and vertical rebar reinforcement in place for bond beams above doors, and ready for 2nd grout lift. Okay to proceed with grout pour.

Third lift.

11/20/23: 4th lift @16’ at East, West and South CMU Block walls. Ok to proceed.
11/22/2023 COT - HCBU - Masonry Pregrout  Partial Pass 4th lift.
11/27/2023 COT - HCBU - Masonry Pregrout  Passed 23’6 6th lift final lift. Rebar per plan. okay for top out all around. 11/27/2023