| 07/25/2025 | COT - HCBU - Framing | Re-inspection required | 7-25-25: H-25A missing nails north glue lam beam, add vertical coil 16 straps at post to beam connection, remove insulation to verify shot pins on metal framing at bathrooms and elsewhere that has not been inspected, missing Simpson H-3 sill plate at columns, missing Simpson ace twin post caps-detail 207, Detail 208 call for steel column-has wood beam-submit revision to reflect framing. | |
| 07/25/2025 | COT - HCBU - Framing | Re-inspection required | 7-25-25: H-25A missing nails north glue lam beam, add vertical coil 16 straps at post to beam connection, remove insulation to verify shot pins on metal framing at bathrooms and elsewhere that has not been inspected, missing Simpson H-3 sill plate at columns, missing Simpson ace twin post caps-detail 207, Submit revision on north new glue lam. beam -plans show existing. East & south framing not inspected-additional items may be added. | |
| 07/30/2025 | COT - HCBU - Framing | Partial Pass | All except termite repair. | |
| 09/17/2025 | COT - HCBU - Framing | Passed |