Permit: TC-COM-0123-00490

Parcel: 13701005H


Addresses:

5500 S NOGALES HY

Inspection Status: Partial Pass

Inspection History: COT - HCBU - Excavation/Rebar/Zoning 

Date Description Inspector Results Comments
06/09/2025 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass 6/9/2025 Detail 104&105 page S4.01 approved in field inspection per south wing of apparatus bay. Okay for concrete placement.
06/28/2024 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass 6/28/24: reinforcement per plan at exterior footings (Dorm Rooms, Day Room, Electric, Lobby, Training(excluding N. Wall), Secured Patio, Captains Office, kitchen, pantry, EMS, Staff patio)
07/03/2024 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass 6/28/24: reinforcement per plan at exterior footings (Dorm Rooms, Day Room, Electric, Lobby, Training(excluding N. Wall), Secured Patio, Captains Office, kitchen, pantry, EMS, Staff patio)
7/3/24: phase 2 reinforcement at footings around exterior perimeter at rooms (144,143,145,146,147 and 149), footing type WF1 and WF2.
07/24/2024 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass 6/28/24: reinforcement per plan at exterior footings (Dorm Rooms, Day Room, Electric, Lobby, Training(excluding N. Wall), Secured Patio, Captains Office, kitchen, pantry, EMS, Staff patio)
7/3/24: phase 2 reinforcement at footings around exterior perimeter at rooms (144,143,145,146,147 and 149), footing type WF1 and WF2.
7/24/24: phase 3 reinforcement at footings per plan ok to proceed with concrete pour.
08/02/2024 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass 6/28/24: reinforcement per plan at exterior footings (Dorm Rooms, Day Room, Electric, Lobby, Training(excluding N. Wall), Secured Patio, Captains Office, kitchen, pantry, EMS, Staff patio)
7/3/24: phase 2 reinforcement at footings around exterior perimeter at rooms (144,143,145,146,147 and 149), footing type WF1 and WF2.
7/24/24: phase 3 reinforcement at footings per plan ok to proceed with concrete pour.
8/2/24: reinforcement per plan at perimeter wall footing. West side of project and Half way of North side.
11/25/2024 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass 6/28/24: reinforcement per plan at exterior footings (Dorm Rooms, Day Room, Electric, Lobby, Training(excluding N. Wall), Secured Patio, Captains Office, kitchen, pantry, EMS, Staff patio)
7/3/24: phase 2 reinforcement at footings around exterior perimeter at rooms (144,143,145,146,147 and 149), footing type WF1 and WF2.
7/24/24: phase 3 reinforcement at footings per plan ok to proceed with concrete pour.
8/2/24: reinforcement per plan at perimeter wall West side of project and Half way of North side.
11/25/24: vertical and horizontal rebar reinforcement at Dorms South, North, East and West wall at 15'4" per plan ok to proceed.
12/03/2025 COT - HCBU - Excavation/Rebar/Zoning  Passed 12-3-25: approved.
12/23/2024 COT - HCBU - Excavation/Rebar/Zoning  Partial Pass 6/28/24: reinforcement per plan at exterior footings (Dorm Rooms, Day Room, Electric, Lobby, Training(excluding N. Wall), Secured Patio, Captains Office, kitchen, pantry, EMS, Staff patio)
7/3/24: phase 2 reinforcement at footings around exterior perimeter at rooms (144,143,145,146,147 and 149), footing type WF1 and WF2.
7/24/24: phase 3 reinforcement at footings per plan ok to proceed with concrete pour.
8/2/24: reinforcement per plan at perimeter wall West side of project and Half way of North side.
11/25/24: vertical and horizontal rebar reinforcement at Dorms South, North, East and West wall at 15'4" per plan ok to proceed.
12/23/24: inspection requested fell under DP inspector for site wall.