Case: T99VL02500

Parcel: 12212049B


Addresses:

1141 N CATALINA AV

Inspection Status: Correction Required

Inspection History: FOLLOW UP CODE VIOLATION

Date Description Inspector Results Comments
02/28/2000 FOLLOW UP CODE VIOLATION Correction Required ADDTL COMMS - 2/25 UNIT 1153 HAD BEEN RENTED AND THE DOUBLE TAPPED A/C WIRE IS STILL PRESENT. TALKED WITH PROPERTY MANAGER ON 2/28 AND HE WILL HAVE DONE IN NEXT TWO DAYS.
02/28/2000 FOLLOW UP CODE VIOLATION Violation VIOLATION
02/18/2000 FOLLOW UP CODE VIOLATION Correction Required ADDTL COMMS - STILL ONE DOUBLE TAP IN BOX FOR UNIT 1153. UNIT REMAINS EMPTY. FLUE PIPE IS STILL DISCONNECTED ON THE HOT WATER HEATER FOR UNIT 1161. UNIT REMAINS EMPTY.
02/18/2000 FOLLOW UP CODE VIOLATION Violation VIOLATION
11/12/1999 FOLLOW UP CODE VIOLATION Compliance COMPLIANCE
10/27/1999 FOLLOW UP CODE VIOLATION Correction Required ADDTL COMMS - PROPERTY WAS INSPECTED BY MYSELF AND WAYNE CUMMINGS OF TFD. THERE WERE NUMEROUS ELECTRICAL VIOLATIONS, HOT WATER HEATER VIOLATIONS, SMOKE DETECTOR VIOLATIONS, BATHROOM WINDOW VENTILATION VIOLATIONS, AND REAR SLIDER DOOR OPERATION FOR EGRESS VIOLATIONS. PROPERTY MANAGER, DALE BIDEGAIN WAS PRESENT FOR THE ENTIRE INSPECTION. N+O TO BE SENT ON 10/28 THERE WERE NUMEROUS ELECTRICAL VIOLATIONS, HOT WATER HEATER VIOLATIONS, SMOKE DETECTOR VIOLATIONS, BATHROOM WINDOW VENTILATION VIOLATIONS, AND REAR SLIDER DOOR OPERATION FOR EGRESS VIOLATIONS. PROPERTY MANAGER, DALE BIDEGAIN WAS PRESENT FOR THE ENTIRE INSPECTION. N+O TO BE SENT ON 10/28
10/27/1999 FOLLOW UP CODE VIOLATION Violation VIOLATION
10/26/1999 FOLLOW UP CODE VIOLATION Correction Required ADDTL COMMS - INSPECTED ALL TWELVE UNITS IN THE COMPLEX. ALL HAVE ELECTRICAL DEFICIENCIES THAT MUST BE CORRECTED. THESE DEFICIENCIES INCLUDE, BUT ARE NOT LIMITED TO, MISSING OUTLET AND SWITCH COVER PLATES, LOOSE OUTLETS, OPEN JUNCTION BOXES, EXTERIOR WIRING NOT IN CONDUIT, DOUBLE TAPPED CIRCUITS IN EXTERIOR PANELS, OPEN FUSE RECEPTICLES AND POSSIBLE MISMATCHED WIRE AND FUSE SIZES, LOOSE LIGHT FIXTURES, NO SMOKE DETECTORS OR INOPERABLE DETECTORS OR MISPLACED DETECTORS. THERE ARE ALSO HOT WATER HEATING UNITS THAT DO NOT HAVE TEMPERATURE/PRESSURE RELIEF VALVES, AND SOME DONOT HAVE EXTENSION PIPES FROM THE T/PR VALVES THAT ARE PRESENT. THERE ARE BROKEN WINDOWS IN MANY UNITS, INOPERABLE BATHROOM WINDOWS IN MANY UNITS AND SLIDING GLASS DOORS THAT ARE INOPERABLE OR BARELY OPERABLE. THERE ARE A COUPLE OF TOILETS THAT NEED TO BE SECURED TO THE FLOOR AND ONE SHOWER MISSING A SHOWER HEAD.
10/26/1999 FOLLOW UP CODE VIOLATION Violation VIOLATION