Permit: T99PL02770

Parcel: 119033400


Addresses:

654 W 43RD ST

Inspection Status: Correction Required

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
01/14/2000 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - REMOVE 3/4 UNION TO RANGE AND CONNECT SOLID.
01/14/2000 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0000*
01/04/2000 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. H. WATER HEATER ENCLOSURE 2. H.W. HEATER VENT NOT CONNECTED NOT SECURE. 3. RUN IRON PIPE INSIDE ENCLOSURE. 4. 10 LBS TEST REQUIRES AIR TEST. 5. CUT BOTTOM THREADS ON P&T DRAIN.
01/04/2000 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0000*
12/30/1999 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. WATER HTR MUST HAVE ENCLOSURE TO PROTECT IT FROM ELEMENTS 2. WATER FTTR P&T DRAIN MUST BE STUB DOWN 6 ABOVE SLAB 3. WATER HTR GAS SHUT OFF VALVE MUST BE AGA APPROVED 4. UNDERGROUND GAS LINE FITTTINGS MUST HAVE PRIMER & TAPE 5. GAS LINE MUST BE SECURED ON WALL WITH APPROVED STRAPS EVERY 8. 6. GAS RANGE MUST HAVE AGA APPROVED SHUT OFF VALVE @ FLEX 7. MUST PROVIDE AIR PRESSURE TEST ON GAS LINE 10 LBS MIN. 8. YOU CAN NOT CONNECT TWO GAS FLEXES TOGETHER REMOVE ONE.
12/30/1999 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0000*