Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T99PL02090

Parcel: 125075760


Addresses:

2020 E 7TH ST


Inspection Status: Correction Required

Inspection History: PLUMBING - FINAL

Permit Number - T99PL02090

Inspection Description - PLUMBING - FINAL

Inspection Status - Correction Required

Date Description Inspector Results Comments
11/17/1999 PLUMBING - FINAL Correction Required ADDTL COMMS - 1. NO CITY APPROVED DRAWING ON SITE 2. NEW UNDERGROUND GAS LINE MUST BE EXPOSED 3. WASTE AND VENT SYSTEM NOT TO PLAN AND CODE 4. WILL REQUIRE PERMIT AND CONNECTION FEES FOR NEW FIXTURES 5. THERE CAN BE NO GAS LINES UNDER STRUCTURE MUST GO OVERHEAD 6. MUST HAVE MIN 12 OF COVER FOR ABS OUTSIDE OF BLDG 7. CAN NOT WET VENT LAVATORY ON A FLAT VENT SYSTEM 8. 3 WASTE LINE HAS LEAKS 9. NO VENT FOR SHOWER OR WATER CLOSET.
11/17/1999 PLUMBING - FINAL Denied IVRS - Inspection 0000*