Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/17/1999 | PLUMBING - FINAL | Correction Required | ADDTL COMMS - 1. NO CITY APPROVED DRAWING ON SITE 2. NEW UNDERGROUND GAS LINE MUST BE EXPOSED 3. WASTE AND VENT SYSTEM NOT TO PLAN AND CODE 4. WILL REQUIRE PERMIT AND CONNECTION FEES FOR NEW FIXTURES 5. THERE CAN BE NO GAS LINES UNDER STRUCTURE MUST GO OVERHEAD 6. MUST HAVE MIN 12 OF COVER FOR ABS OUTSIDE OF BLDG 7. CAN NOT WET VENT LAVATORY ON A FLAT VENT SYSTEM 8. 3 WASTE LINE HAS LEAKS 9. NO VENT FOR SHOWER OR WATER CLOSET. | |
11/17/1999 | PLUMBING - FINAL | Denied | IVRS - Inspection 0000* |