Permit: T99PL01910

Parcel: 129051670


Addresses:

2019 E 18TH ST

Inspection Status: Correction Required

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
09/09/1999 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. GAS PRESSURE TEST OK 2. GAS SHUT OFF VALVE OK 3. WATER HTR FLU VENT P&T DRAIN OK 4. WATER HTR ENCLOSURE OK 5. OK TO BACKFILL TRENCH
09/01/1999 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. MUST TAPE PRIMER AND TAPE UP ALL FITTINGS UNDERGROUND 2. REMOVE UNION BY METER OR INSTALL AGA APPROVED GAS SHUT OFF VALVE 3. FLU PIPE FOR WATER HTR MUST BE DBL WALL W/CAP GOING THRU ROOF 4. WATER HTR MUST HAVE ENCLOSURE TO PROTECT HTR FROM ELEMENTS 5. MUST HAVE 10 LBS PRESSURE TEST
09/01/1999 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0000*