Permit: T99PL01659

Parcel: 111051680

Inspection Status: Correction Required

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
08/17/1999 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. GAS PRESSURE TEST OK 2. GAS SHUT OFF VALVES OK 3. WATER HTR P&T DRAIN LINE OK
08/12/1999 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. PVC IS NOT THE APPROVED MATERIAL FOR P&T DRAIN LINE MUST BE COPPER OR CPVC 2. P&T DRAIN MUST BE PIPED TO 6 ABOVE GROUND
08/12/1999 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0000*
08/05/1999 PLUMBING - GAS PRESSURE TEST Correction Required ADDTL COMMS - 1. MUST SEE AGA APPROVED GAS VALVES FOR EACH APPLIANCE 2. P&T DRAIN LINE MUST BE THE SAME SIZE AS OUTLET OF P&T VALVE 3/4
08/05/1999 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0000*