Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/15/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - HOLDDOWNS IN FRONT ENTRYWAY NEED TO BE APPLIED PER MANUFACTURES SPECS. OKAY TO LATH HOUSE EXCEPT FRONT ENTRY. NO CITY OF TUCSON APPROVED TRUSS CALCULATIONS. |
| 02/14/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - DENIED - STOPPED INSPECTION 1. EXTERIOR SHEARWALL #4 EAST WALL, NAIL PER SCHEDULE. ALSO AT NORTH WALL. 2. COMMON WALL AT GARAGE NAILING SCHEDULE IS 3O.C. 3. MASONRY HOLDDOWNS AT FRONT DOOR ARE NOT INSTALLED PROPERLY. NEED TO BE NAILED TO 2 CONTINUOUS 2 XS. 4. CLIP ALL GIRDER TRUSSES BOTH SIDES AND POST PER DETAIL. SD2/2. 5. HINGE BRACING IS NOT INSTALLED PER PLAN. 6. PROVIDE TRUSS CALCULATIONS FOR SMALLER JACK TRUSSES INSTALLED. |
| 02/14/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
DENIED |
| 02/11/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - CANCELLED BY CONTRACTOR. |
| 02/11/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 02/08/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Correction Required |
ADDTL COMMS - DENIED - ROOF NAIL NAIL OFF VENT BOARDS. LOOSE PANELS THROUGHOUT. NAIL DOWN OR REMOVE SHINERS. HINGE NAILING. 4 NAILS 16DS THROUGH HINGE INTO BLOCK. IDENTIFY NAILS THROUGH ROOF 8DS 6O.C. PROVIDE CROSS BRACING MID-SPAN TRUSSES. PROVIDE H25S. BOTH SIDES OF GIRDER AND POST. BOTH STUDS TOP AND BOTTOM. PROVIDE HOLD-DOWN EAST WALL GARDEN WINDOW. NAIL OFF SHEARWALLS PER PLAN THROUGHOUT. |
| 02/08/2000 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* |