Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Correction Required
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 03/10/2000 |
PLUMBING - GAS PRESSURE TEST |
|
Correction Required |
ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. GAS PRESSURE TEST OK 4. ALL CORRECTIONS HAVE BEEN MADE 5. OK TO DRYWALL 6. NOTE: GREASE TRAP NOT INSTALLED AT THIS TIME |
| 03/10/2000 |
PLUMBING - GAS PRESSURE TEST |
|
Correction Required |
ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. GAS PRESSURE TEST OK 4. ALL CORRECTIONS HAVE BEEN MADE 5. OK TO DRYWALL 6. NOTE: GREASE TRAP NOT INSTALLED AT THIS TIME |
| 03/09/2000 |
PLUMBING - GAS PRESSURE TEST |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 03/07/2000 |
PLUMBING - GAS PRESSURE TEST |
|
Correction Required |
ADDTL COMMS - 1. GAS PRESSURE TEST WAS DOWN TO ZERO LBS 2. GAS LINE MUST BE AT LEAST 6 A.F.F. SEE SECTION 1211.3 UPC 3. 2 GAS LINE MUST BE SUPPORTED EVERY 10 4. ALL ABS HORIZONTAL VENTS MUST BE HUNG OR STRAPED EVERY 4. 5. NO WATER TEST ON WASTE SYSTEM 6. NO CLOSET RINGS INSTALLED 7. NO P&T DRAIN FOR WATER HTR INSTALLED 8. LOTS OF LOOSE COPPER WATER LINES ON HORIZONTAL AND VERTICAL DROPS. 9. GREASE TRAP NOT INSTALLED AT THIS TIME. |
| 03/07/2000 |
PLUMBING - GAS PRESSURE TEST |
|
Denied |
IVRS - Inspection 0000* |