Inspection Status: Correction Required
Inspection History: PLUMBING - ABOVE CEILING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/10/2000 |
PLUMBING - ABOVE CEILING |
|
Correction Required |
ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. GAS PRESSURE TEST OK 4. ALL CORRECTIONS HAVE BEEN MADE 5. OK TO DRYWALL 6. NOTE: GREASE TRAP NOT INSTALLED AT THIS TIME |
| 03/10/2000 |
PLUMBING - ABOVE CEILING |
|
Correction Required |
ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUTION OK 3. GAS PRESSURE TEST OK 4. ALL CORRECTIONS HAVE BEEN MADE 5. OK TO DRYWALL 6. NOTE: GREASE TRAP NOT INSTALLED AT THIS TIME |
| 03/09/2000 |
PLUMBING - ABOVE CEILING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 03/07/2000 |
PLUMBING - ABOVE CEILING |
|
Correction Required |
ADDTL COMMS - 1. GAS PRESSURE TEST WAS DOWN TO ZERO LBS 2. GAS LINE MUST BE AT LEAST 6 A.F.F. SEE SECTION 1211.3 UPC. 3. 2 GAS LINE MUST BE SUPPORTED EVERY 10 4. ALL ABS HORIZONTAL VENTS MUST BE HUNG OR STRAPED EVERY 4. 5. NO WATER TEST ON WASTE SYSTEM 6. NO CLOSET RINGS INSTALLED 7. NO P&T DRAIN FOR WATER HTR INSTALLED 8. LOTS OF LOOSE COPPER WATER LINES ON HORIZONTAL AND VERTICAL DROPS 9. GREASE TRAP NOT INSTALLED AT THIS TIME. |
| 03/07/2000 |
PLUMBING - ABOVE CEILING |
|
Denied |
IVRS - Inspection 0000* |