Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T99CM05931
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2000 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000* WET VENTED SECTION CORRECTED OK TO COVER |
|
10/04/2000 | PLUMBING - INTERMEDIATE | Denied | 10/04/00 1. SEE 908.1 WET VENTING LI ITED TO VERTICAL PIPING 2. PACK THE LEAD ON THE CLOSET FLANGE 3. TIE WIRE NOT APPROVED STRAP 4. ISOLATE COPPER WHERE TOUCHING METAL INCLUDING STUDS 5. MAKE SURE COPPER IS BRACED ADEQUELTY |