Permit: T99CM05931

Parcel: 20914001C


Addresses:

6205 S AIRFIELD DR


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T99CM05931

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/10/2000 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
WET VENTED SECTION CORRECTED
OK TO COVER
10/04/2000 PLUMBING - INTERMEDIATE Denied 10/04/00 1. SEE 908.1 WET VENTING LI ITED TO VERTICAL PIPING
2. PACK THE LEAD ON THE CLOSET FLANGE
3. TIE WIRE NOT APPROVED STRAP
4. ISOLATE COPPER WHERE TOUCHING METAL INCLUDING STUDS
5. MAKE SURE COPPER IS BRACED ADEQUELTY