Inspection Status: Correction Required
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 02/08/2000 |
ELECTRIC - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - CHECK W/REGISTRAR VALVE ELEC CARLOS CANYZ |
| 02/03/2000 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 02/01/2000 |
ELECTRIC - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - NEED L-11 LIC CONTRACTOR TO FINISH JOB |
| 02/01/2000 |
ELECTRIC - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 01/31/2000 |
ELECTRIC - INTERMEDIATE |
|
Correction Required |
ADDTL COMMS - 1. GROUND ALL METAL BOXES PER ART. 250 N.E.C. (ATTIC) 2. REMOVE ALL UNUSED N.M. CONNECTORS AND SEAL UNUSED OPENINGS 110-124 & 373-4 3. PER ART 300-14 LEAVE AT LEAST 6 OF CONDUCTOR. REWORK REPULL CABLE TO ACHIEVE THIS MIN REQUIREMENT OF ART 300-14 NATIONAL ELEC, CODE 4. FIRE CAULK ALL FIRE WALL PENETRATIONS AND SLEEVE PER N.E.C. FINISH BOX MAKE UP OF EQUIP GROUNDING CONDUTORS AND NEUTRALS (GROUNDING CONDUCTORS) PRIOR TO INSPECTION |
| 01/31/2000 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999$ |