Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T99CM05802
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/27/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
02/16/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1. NAIL PROTECT ABS PLUMBING WITHIN 1 1/4" OF STUD SURFACE ON SECOND FLOOR SEVERAL PLACES AND KITCHENS. 2. FIRE/DRAFT STOP FURR OUT FOR 3" WASTE STACK IN LIVING ROOM. 3. BACK GROUT FLOOR PENETRATION FOR TUB. 4. ANCHOR BOLTS EXCEED 48" O.C. 2 PLACES NORTHWALL. 1/5. 5. BEDROOM 4 BEARING WALL REQUIRES RAMSETS AT 32" O.C. AND STAIR BEARING WALL. 23/5. 6. STAIR HEADER CRIPPLES MUST BE TIGHT AT DOUBLE PLATE. REPLACE DO NOT SHIM. ALSO ABOVE WINDOW HEADERS. 7. BEDROOM 4 DOOR REQUIRES 3-2X10 BEAM HEADER. 8. TRIMMERS MUST BE NAILED TO KING STUDS AT 24" O.C. 9. PORCH NOT INSTALLED. |