Permit: T99CM05774

Parcel: 115071800


Addresses:

49 E ADAMS ST


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T99CM05774

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/04/2001 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection 0000*
11/20/2000 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*/1. ZIP CHORD (LITE POWER) IS NOT ALLOWED TO PENETRATE DRYWALL. ALL ELECTRIC OUTLET BOXES MUST BE ACCESSABLE (LIGHTS). 2. IF 220 VOLT OUTLET IN GARAGE IS FOR A CLOTHES DRYER THEN IT MUST BE A 4 WIRE CIRUIT 2 HOT ONE NEUTRAL 1 GROUND. 3. ELECTRIC OUTLET BOXES MUST EXTEND TO WITHIN 1/4" OF DRYWALL SURFACE.
07/28/2000 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection 0999*/1. OUTSIDE METAL ELECTRIC BOXS NOT PROPERLY GROUNDED SEE NOTE. 2. THE GROUND WIRES ON THE INSIDE AND OUTISDE ELECTRIC BOXES WITH 2 ROMEX CABLES MUST HAVE THE GROUNDS TWISTED TOGETHER WITHIN ADDED PIGTAIL AND SECURED WITH A WIRE NUT.
06/22/2000 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection 0000*/1. THE ELECTRIC BOX ON THE EAST SIDE OF THE PERSONNEL DOOR 6 FT UP MUST BE EXTENDED AND ACCESSABLE AFTER WALL IS DRYWALLED NOTE: FOR YOUR ELECTRIC SERVICE RELOCATION YOU WILL HAVE TO TALK TO A PERMIT SPECIALIST AT 791-5550 TO GET THE SERVICE INCREASE AND RELOCATION ON YOUR PERMIT. THE GROUND ROD LOCATIONS ARE OK BUT THE NEW NON METALLIC CONDUIT BETWEEN PANELS MUST BE AT LEAST 20" DEEP TO OBTAIN 18" COVER.
04/11/2000 ELECTRIC - INTERMEDIATE Denied DENIED