Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
02/29/2000 FRAMING Correction Required ADDTL COMMS - APPROVED AS NOTED: HAVE VEGA INSTALLATION PUT ON PLANS.
02/14/2000 FRAMING Correction Required ADDTL COMMS - NOT READY - FIREPLACE CHASE IS TO BE FIRE BLOCKED. BLOCK AT SOFFIT OR ENCLOSE CHASE WITH PLY WOOD. ISOLATE CHASE FROM INTERIOR SPACES.
02/14/2000 FRAMING Not ready for Inspection NOT READY FOR INSPECTION
02/02/2000 FRAMING Correction Required ADDTL COMMS - 1. FIRE STOP FIREPLACE CEILING. 2. NAIL PROTECT MASTER BATH LAVATORY PEX. 3. TJIS MUST BEAR ON INTERIOR BEARING WALL. 4. SUPPORT 3/4 GAS LINE AT 8 O.C. AND NOT ON PLUMBERS TAPE.
02/02/2000 FRAMING Denied IVRS - Inspection 0999*