Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/29/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - APPROVED AS NOTED: HAVE VEGA INSTALLATION PUT ON PLANS. |
| 02/14/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - NOT READY - FIREPLACE CHASE IS TO BE FIRE BLOCKED. BLOCK AT SOFFIT OR ENCLOSE CHASE WITH PLY WOOD. ISOLATE CHASE FROM INTERIOR SPACES. |
| 02/14/2000 |
FRAMING |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 02/02/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. FIRE STOP FIREPLACE CEILING. 2. NAIL PROTECT MASTER BATH LAVATORY PEX. 3. TJIS MUST BEAR ON INTERIOR BEARING WALL. 4. SUPPORT 3/4 GAS LINE AT 8 O.C. AND NOT ON PLUMBERS TAPE. |
| 02/02/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |