Inspection Status: Correction Required
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/14/2000 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - APPROVED AS NOTED: SEPARATE YOUR PAPERWORK AND GET ANOTHER SET OF PLANS. ONE FOR EACH HOUSE. |
| 03/13/2000 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - DENIED - NO PLANS ON JOB SITE. |
| 03/13/2000 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999* |
| 03/10/2000 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - DENIED - 1. NO WATER TEST ON ROUGH PLUMBING. 2. DRAIN LINES MUST BE CONTINUOUSLY SUPPORTED SHADE LINES TO CENTER LINE. UNCOVER ALL COVERED FITTINGS AND CONNECTIONS. NOTE: STEM WALL SHOULD HAVE VERTICAL REBAR AT DEPRESSED LOCATIONS. PROVIDE APPROVED REPAIR PRIOR TO PRE-SLAB APPROVAL. SEE 3/S3. |
| 03/10/2000 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999* |