Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T99CM05759
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/04/2000 | FRAMING | Approved | IVRS - Inspection 0000* | |
05/09/2000 | FRAMING | Correction Required | ADDTL COMMS - EXCLUDES PORCH COLUMN | |
05/09/2000 | FRAMING | Partial Approval | IVRS - Inspection 0000* | |
05/08/2000 | FRAMING | Denied | IVRS - Inspection 0999*/1. NO TEST ON GAS LINE. 2. MISSING ANCHOR BOLTS ON BOTTOM PLATE. 3. MISSING CLIP ON TRUSS. 4. NEED BRACING ON TRUSSES. 5. PORCH COLUMN IN FRONT OF HOUSE MISSING. 6. GROUND METAL BOXES. 7. NEED 2" VENT ON KITCHEN SINK. 8. NEED 2" VENT AT MASTER BATH. 9. SUPPORT ELECTRICAL BOX AT KITCHEN ENTRY WAY. 10. MISSING CLIPS AT PORCH RAFTERS. 11. SHEATHIN NOT NAILED CORRECTLY 12. ROOF NAILING NOT COMPLETED 13. MISSING OUTLET IN FRONT ROOM AND HALLWAY. | |
05/05/2000 | FRAMING | Correction Required | ADDTL COMMS - NO PLANS OR PERMIT ON SITE | |
05/05/2000 | FRAMING | Denied | IVRS - Inspection 0999* |