Inspection Status: Correction Required
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/29/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - APPROVED AS NOTED: HAVE VEGA INSTALLATION PUT ON PLANS. |
| 02/14/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. CALL BACK FOR VEIGA INSTALL. 2. NEED SPARK PROTECTION AT FIREPLACE. 3. USE NAILS IN SHEAR, NOT WITHDRAWL AT VEIGA HANGERS. USE BLOCKS ATTACHED TO WEB. DONT NAIL INTO CHORDS. 4. PROTECT PEX AT GARAGE, LAST INSPECTION. 5. NEED PPYRO CURE AT FIREPLACE CHASE. 6. TEMPERED GLASS AT BALCONY. |
| 02/14/2000 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 02/02/2000 |
FRAMING |
|
Correction Required |
ADDTL COMMS - 1. NAIL PROTECT PEX AT SERVICE ENTRANCE TOP PLATE. 2. REVERSE FLOW ON LAUNDRY VENT. 3. FIRE BLOCK STAIRS. 4. HEADERS MUST BEAR ON TRIMMERS, LOWER BEDROOM, UPPER BEDROOM. 5. RED-HEAD ANCHOR BOLTS LOOSE. 6. SECURE 4 SWITCH ELECTRIC BOXES AT EACH END UPSTAIRS. 7. FIRE PLACE OFFSET ELBOW STRAPS MUST BE SECURED TIGHTLY AT 45 DEGREE ANGLE. 8. METAL STRIP NOT INSTALLED AT FRONT OF FIREPLACE. 9. SUPPORT HORIZONTAL DRAIN AT 4 O.C. NOTE: THE FLOORS SQUEAK IN UPPER BEDROOM. |
| 02/02/2000 |
FRAMING |
|
Denied |
IVRS - Inspection 0999* |