Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
02/29/2000 FRAMING Correction Required ADDTL COMMS - APPROVED AS NOTED: HAVE VEGA INSTALLATION PUT ON PLANS.
02/14/2000 FRAMING Correction Required ADDTL COMMS - 1. CALL BACK FOR VEIGA INSTALL. 2. NEED SPARK PROTECTION AT FIREPLACE. 3. USE NAILS IN SHEAR, NOT WITHDRAWL AT VEIGA HANGERS. USE BLOCKS ATTACHED TO WEB. DONT NAIL INTO CHORDS. 4. PROTECT PEX AT GARAGE, LAST INSPECTION. 5. NEED PPYRO CURE AT FIREPLACE CHASE. 6. TEMPERED GLASS AT BALCONY.
02/14/2000 FRAMING Not ready for Inspection IVRS - Inspection 0000*
02/02/2000 FRAMING Correction Required ADDTL COMMS - 1. NAIL PROTECT PEX AT SERVICE ENTRANCE TOP PLATE. 2. REVERSE FLOW ON LAUNDRY VENT. 3. FIRE BLOCK STAIRS. 4. HEADERS MUST BEAR ON TRIMMERS, LOWER BEDROOM, UPPER BEDROOM. 5. RED-HEAD ANCHOR BOLTS LOOSE. 6. SECURE 4 SWITCH ELECTRIC BOXES AT EACH END UPSTAIRS. 7. FIRE PLACE OFFSET ELBOW STRAPS MUST BE SECURED TIGHTLY AT 45 DEGREE ANGLE. 8. METAL STRIP NOT INSTALLED AT FRONT OF FIREPLACE. 9. SUPPORT HORIZONTAL DRAIN AT 4 O.C. NOTE: THE FLOORS SQUEAK IN UPPER BEDROOM.
02/02/2000 FRAMING Denied IVRS - Inspection 0999*