Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T99CM05519
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/02/2000 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - APPROVED AS NOTED: NEED DRAFT STOP BETWEEN TENANT. |