Inspection Status: Correction Required
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/30/2000 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - APPROVED - 1. BATHROOM OUTLET TO BE ON A SEPARATE 20 AMP CIRCUIT #12 WIRE. 2. CLOSET RING MUST HAVE 15 TO CENTER LINE MINIMUM ON EACH SIDE. |
| 03/23/2000 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - NOT READY - 1. LOOSE ROOF. PLY OLD TYPE. NEED A CRICKET ON EACH END TO DIVERT WATER AWAY FROM CORNERS. 2. 2 VENTS TO PENETRATE ROOF. |
| 03/23/2000 |
ROOF NAILING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |