Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/19/2000 |
SHEET ROCK NAILING |
|
Approved |
|
| 02/04/2000 |
SHEET ROCK NAILING |
|
Denied |
DENIED |
| 01/28/2000 |
SHEET ROCK NAILING |
|
Correction Required |
ADDTL COMMS - 1. CANNOT APPROVE DRYWALL UNTIL FRAME IS APPROVED. 2. SOUTH WALL PARAPET WALL IS NOT CONNECTED TO MASONARY WALL BELOW. 3. GAS LINE AT S.W. PORCH CANNOT RUN UNDER COVERED SLAB. 4. COPPER WATER LINES EXTENDING THROUGH MASONRY WALLS MUST BE PROPERLY PROTECTED. 5. EAST PORCH LAUNDRY WASHER TRAP CANNOT BE MORE THAN 18. 6. EAST PORCH RAFTERS CANNOT BE SPLICED WITH BOLTS. MUST BEAR ON LEDGER. 7. SOUTH END OF EAST PORCH BEAM IS NOT SECURED TO BEARING MASONARY WALL BELOW. 8. EXTERIOR DOOR HAS BEEN ADDED TO BATH OR BEDROOM 1, AND REQUIRES HEADER AT DOOR AND PLAN REVISED. 9. BEDROOM 1, BATHROOM WATER CLOSET REQUIRES A 2 VENT. 10.3-1/2 X 3-1/2 X 1/4 ANGLE IRON HAS BEEN USED AS ADDED LENTALS INSIDE AND OUT FOR 4 ADDED WINDOWS ON NORTH AND WEST WALLS. THE LINTELS ARE NOT SECURED TO THE WALLS AND DO NOT CARRY THE LOAD OF THE MASONARY WALLS. PROVIDE ENGINEERING APPROVAL AND DESIGN OF LINTELS. 10.YARD WATER LINE MUST BE 12 BELOW GRADE. 11.PORCH ON SOUTH AND WESTSIDE OF HOUSE NOT ON PLAN. REVISE PLAN TO AS BUILT. 12.WINDOW IN BEDROOM 1 HAS BEEN ENLARGED AND CHANGED. WINDOW DOES NOT MEET MINIMUM WIDTH REQUIREMENT OF 10 OPENING FOR EGRESS. 13.BEDROOMS HAVE INADEQUATE NATURAL LIGHT: ALL WINDOWS HAVE BEEN CHANGED. BEDROOM 1, 145 SF - WINDOW 11SF GLASS AREA. BEDROOM 2, 124 ST - WINDOW 9.75 SF GLASS AREA. |
| 01/28/2000 |
SHEET ROCK NAILING |
|
Correction Required |
MORE ADDTL COMMS - BEDROOM 3, 130 SF - WINDOW 9.75 SF GLASS AREA. 14.BACK GROUT ALL FLOOR PENETRATIONS FOR TUBS, SHOWER AND WATER CLOSETS. 15.SHOWER VALVE NOT PROPERLY SECURED. 16.NO HUB CLAMP ON SHOWER VENT LOOSE. 17.GROUND ALL METAL ELECTRIC BOXES AND MAKE UP GROUND WIRES IN ALL BOXES. |
| 01/28/2000 |
SHEET ROCK NAILING |
|
Denied |
DENIED |
| 01/19/2000 |
SHEET ROCK NAILING |
|
Correction Required |
ADDTL COMMS - 1. NO APPROVED PLANS - STOPPED INSPECTION. 1. NO VENT PROVIDED AT LAUNDRY - NO CLEAN OUT PROVIDED. 3. NO APPROVED GAS TEST. 4. PLUMBING AT BATHTUBS NOT COMPLETE. FLOORS NOT GROUTED IN 2 BATHROOMS. 5. NO RETURN AIR DUCT PROVIDED FOR SYSTEM/PLANS DO NOT SHOW DINING ROOM, COMPUTER ROOM AND 3RD BATH. 6. FRAMING NOT COMPLETE INSIDE THE HOUSE. 6. FRAMING NOT COMPLETE INSIDE THE HOUSE. 7. WATER HEATER VENT PIPE NOT APPROVED. PROVIDE 1 CLEARANCE FROM COMBUSTIBLES. 8. BACK PORCH SLIPPING NOT COMPLETE. PORCH BEAM CANTILEVERED 5-0 WITH NO SUPPORT. NOT ON PLANS AND NO DETAIL. 9. FRONT PORCH NOT ON PLANS AND MAY BE IN ZONING VIOLATION. 10.HEADERS INSTALLED INCORRECT AROUND HOUSE. 11.SMOKE DETECTORS NEED TO BE CHECKED. 12.CHECK REAR PORCH RAFTERS FOR APPROVED DETAIL. 13.MASONRY LINTELS NOT INSTALLED CORRECT, MANY MISSING COMPLETELY. 14.BEAMS AND RIDGE BOARDS PLACED INTO MASONRY INCORRECT. 15.PARAPET ON SOUTHSIDE INSTALLED WITHOUT INSPECTIONS. |
| 01/19/2000 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0999* |