Permit: T99CM05349

Parcel: 137294000


Addresses:

1882 W SAVOY PL

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
02/22/2000 FRAMING Correction Required ADDTL COMMS - 1. INTERIOR SHEARWALLS ARE NOT PER DETAIL 18A/SD3. 2. MID-SPAN CROSS BRACING TRUSSES. 3. PROVIDE BACKING ACCESS PANEL FOR BLOWN INSULATION. 4. PROVIDE CLEARANCE AT FURNACE FLUE.
02/22/2000 FRAMING Denied DENIED
02/16/2000 FRAMING Correction Required ADDTL COMMS - NOT READY - CANCELLED BY SUPERINTENDENT.
02/16/2000 FRAMING Not ready for Inspection IVRS - Inspection 0000*
02/14/2000 FRAMING Correction Required ADDTL COMMS - DENIED - STOPPED INSPECTION 1. GIRDER TRUSS IS NOT CLIPPED PER PLAN. DETAIL SD2/2. 2. JACK TRUSSES MISSING HARDWARE. 3. REMOVE COMBUSTIBLE MATERIAL FROM FLUE VENTS. 4. PROVIDE A 30 WORKSPACE IN FRONT OF FURNACE WITH NO OBSTRUCTIONS. 5. PROVIDE DETAIL 15/SD3 AT GARAGE. 6. PROVIDE ENGINEERS APPROVAL FOR CHANGE IN SHEAR TRANSFER. 7. PROVIDE FULL SCREEN RAFTER TRUSS EAVE VENT AND BAFFLES.
02/14/2000 FRAMING Denied DENIED
02/11/2000 FRAMING Correction Required ADDTL COMMS - CANCELLED BY CONTRACTOR. RESCHEDULE.
02/11/2000 FRAMING Not ready for Inspection NOT READY FOR INSPECTION
12/29/1999 FRAMING Correction Required ADDTL COMMS - COMPLETE ALL TRADES BEFORE CALLING FOR INSPECTION
12/29/1999 FRAMING Denied IVRS - Inspection 0999*