Inspection Status: Correction Required
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/10/2000 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - 1. SOIL EATER TEST OK 2. APPROVED DRAWING OK 3. HCS CONNECTION OK 4. OK TO BACKFILL TRENCH. |
| 01/06/2000 |
PLUMBING - ROUGH, SOIL |
|
Correction Required |
ADDTL COMMS - 1. 3 SAN CROSS NOT TO CODE, YOU MUST USE 3 DBL COMBO FOR WATER CLOSETS 2. BACK TO BACK LAVATORYS MUST ALSO HAVE 2X1 1/2 DBL FIX TURE FITTING IN ORDER TO USE SAN CROSS BARREL OF DRAIN MUST BE (2) PIPE SIZES LARGER, SEE SECTION 706.2 UPC 3. WILL REQUIRE REVISED AND APPROVED DRAWING OF PLDG. IZO FOR W.C. FROM 4 TO 3 BEFORE FINAL 4. RE TEST SYSTEM. |
| 01/06/2000 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0000* |