Inspection History: SEPTIC - SYSTEM

Date Description Inspector Results Comments
04/06/2000 SEPTIC - SYSTEM Correction Required ADDTL COMMS - APPROVED AS NOTED: SEPTIC SYSTEM LOCATED AND BUKLT PER DEQ PLAN.
04/03/2000 SEPTIC - SYSTEM Correction Required ADDTL COMMS - DENIED - 1. PROVIDE PROPER SEAL CONNECTIONS AT THE IN SIDE AND OUT SIDE OF SEPTIC TANK. 2. PROVIDE CLEAN FILL UNDER PIPE BETWEEN LEACH FIELDS. 3. IS THE MESH COVERING THE LEACH FIELDS BIODEGRADABLE? 4. EFFECTIVE DEPTH RODS WERE NOT PLACED IN THE WEST TRENCH.
04/03/2000 SEPTIC - SYSTEM Denied IVRS - Inspection 0999*