Permit: T99CM05296

Parcel: 10319002G

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/28/2000 BUILDING - FINAL Approved IVRS - Inspection 0000*
12/26/2000 BUILDING - FINAL Denied IVRS - Inspection 0950*
12/19/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*/1. PROVIDE A SERVICE RECEP. OUTLET WITHIN 25' OF AC DISCONNECT SHALL BE GFCI PROTECTED. 2. IDENTIFY ALL CIRCUIT BREAKERS AT ELEC. PANEL. 3. SHORT CIRCUIT ON CIRCUIT #11 CORRECT. 4. POST PROPERTY #'S 3" MINIMUM LETTERS. 5. KITCHEN RECEPS FOR COUNTER MUST BE PROTECTED "GFCI" 6. BATHROOM GFCI RECEPS NOT WORKING TOGETHER. 7. PROVIDE P TRAP FOR FURNACE. 8. PROVIDE CLEANOUT FOR LAUNDRY TUB. 9. SELF CLOSING DOOR NOT APPROVED NEEDS TO BE SELF CLOSING AND STAMPED FOR USE INTENDED SOLID CORE DOOR. 10. PROVIDE BOND WIRE FOR GAS LINES.
12/18/2000 BUILDING - FINAL Denied IVRS - Inspection 0999*
11/15/2000 BUILDING - FINAL Prior to Final Inspectn CHECK 1041 U VALUE FOR WINDOW. PROVIDE PRESSURE TEST BY FINAL