Inspection Status: Correction Required
Inspection History: PLUMBING - ABOVE CEILING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/29/2000 |
PLUMBING - ABOVE CEILING |
|
Correction Required |
ADDTL COMMS - 1. WASTE AND VENT SYSTEM OK 2. OVERHEAD WATER DISTRIBUITON OK 3.OK TO DRYWALL |
| 02/16/2000 |
PLUMBING - ABOVE CEILING |
|
Correction Required |
ADDTL COMMS - 1. ROUGH PLUMBING NOT TO PLAN AND SPECS 2. SPECS CALL FOR CAST IRON NO HUB 3. 2 DIRTY ARMS EXCEEDS 135 DEGREES A CLEAN OUT IS REQUIRED WHEN WASTE LINE EXCEEDS 135 DEGREES BUT CANNOT BE ON DIRTY ARM 4. NO ROUGH PLDG FOR P-3? 5. OVERHEAD WATER DISTRIBUTION NOT TO PLAN |
| 02/16/2000 |
PLUMBING - ABOVE CEILING |
|
Denied |
IVRS - Inspection 0000* |