Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Correction Required
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/07/2000 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - 1. (10/DT1) NOT COMPLIED WITH. 2. (13/DT1) NOT PER PLAN. |
| 01/07/2000 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999* |
| 01/06/2000 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - 1. 10/DT1 NOT COMPLIED WITH-CALLS FOR BLOCKS 12 O.C. 2. 13/DT1 SHEAR AT GARAGE NOT PER PLAN. |
| 01/06/2000 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999* |
| 11/23/1999 |
ROOF NAILING |
|
Correction Required |
ADDTL COMMS - 1. FRAMING NOT COMPLETE. 2. PATIO NOT COMPLETE. 3. TC24S NAILED INCORRECT OR MISSING NAILS. 4. DETAILS 5,6,7,8,9,10,12,13 NOT COMPLIED WITH. 5. PLANS CALL FOR (2) 2X6 POST BOTH SIDE OF GARAGE ENTRY. 6. BIRD BLOCKS NOT COMPLETELY NAILED OFF. 7. MANY SHINERS THROUGH ROOF DECKING AND LOOSE PANELS. |
| 11/23/1999 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999* |