Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Correction Required
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T99CM04886
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/04/1999 | PLUMBING - ROUGH, SOIL | Correction Required | ADDTL COMMS - 1. SOIL WATER TEST OK 2. ALL CORRECTIONS HAVE BEEN MADE 3. OK TO BACKFILL TRENCH | |
12/02/1999 | PLUMBING - ROUGH, SOIL | Correction Required | ADDTL COMMS - 1. WILL REQUIRE REVISED AND APPROVED DRAWING ON WASTE LINE @ RESTROOM 2. FERNCO COUPLINGS ARE NOT APPROVED FOR INTERIOR OF STRUCTURE 3. SPECS ON DRAWING SHOW WASTE AND VENT SYSTEM TO BE CAST IRON NO HUB. PLEASE PROVIDE LETTER FROM ENGINEER THAT ABS SCH 40 IS OK. | |
12/02/1999 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0000* |